10 Rheem Heating, Cooling and Water Heating
Model/Nominal
Cooling Tons
Voltage Phase Hertz HP [W] RPM Speeds
Circuit
Amps.
Minimum
Circuit
Ampacity
Maximum
Circuit
Protector
RHAL18 208/230 1 60 1/5 [149] 1075 2 1.5 3 15
RHAL30 208/230 1 60 1/4 [186] 1075 2 2.5 4 15
RHAL24 208/230 1 60 1/5 [149] 1075 2 1.5 3 15
RHAL36 208/230 1 60 1/3 [249] 1075 2 2.5 4 15
RHBL24 208/230 1 60 1/3 [249] 300-1100 4 1.6 3 15
RHBL36 208/230 1 60 1/2 [373] 300-1100 4 2.7 4 15
RHAL/RHBL Electrical Data – Blower Motor Only – No Electric Heat
*Blower motors are all single phase motors.
Cooling
Capacity Tons
Heater
kW
(208/240V)
PH/Hz
No. Elements -
kW Per
Type Supply
Circuit
Circuit
Amps.
Motor
Ampacity
Maximum
Circuit
Protection
RHAL
18
2.25/3.0 1/60 1-3.0 Single 10.8/12.5 1.5 20/20
3.6/4.8 1/60 1-4.8 Single 17.3/20.0 1.5 25/30
5.4/7.2 1/60 2-3.6 Single 26.0/30.0 1.5 35/40
Model
No.
RXHJ-21B/T05J
RXHJ-21B/T03J
RXHJ-21B/T08J
Minimum
Circuit
Ampacity
24/27
16/18
35/40
RHAL/RHBL
24
RXHJ-21B/T03J 2.25/3.0 1/60 1-3.0 Single 10.8/12.5 1.5 16/18 20/20
RXHJ-21B/T05J 3.6/4.8 1/60 1-4.8 Single 17.3/20.0 1.5 24/27 25/30
RXHJ-21B/T08J 5.4/7.2 1/60 2-3.6 Single 26.0/30.0 1.5 35/40 35/40
RXHJ-21B/T10J 7.2/9.6 1/60 2-4.8 Single 34.6/40.0 1.5 46/52 50/60
RHAL
30
RXHJ-24B/T03J 2.25/3.0 1/60 1-3.0 Single 10.8/12.5 2.5 17/19 20/20
RXHJ-24B/T05J 3.6/4.8 1/60 1-4.8 Single 17.3/20.0 2.5 25/29 25/30
RXHJ-24B/T08J 5.4/7.2 1/60 2-3.6 Single 26.0/30.0 2.5 36/41 40/45
RXHJ-24B/T10J 7.2/9.6 1/60 2-4.8 Single 34.6/40.0 2.5 47/54 50/60
RHAL/RHBL
36
RXHJ-24B/T03J 2.25/3.0 1/60 1-3.0 Single 10.8/12.5 2.5 17/19 20/20
RXHJ-24B/T05J 3.6/4.8 1/60 1-4.8 Single 17.3/20.0 2.5 25/29 25/30
RXHJ-24B/T08J 5.4/7.2 1/60 2-3.6 Single 26.0/30.0 2.5 36/41 40/45
RXHJ-24B/T10J 7.2/9.6 1/60 2-4.8 Single 34.6/40.0 2.5 47/54 50/60
RHAL/RHBL Electrical Data – with Electric Heat
Installation of the U.L. Listed original equipment manufacturer provided heater kits listed in the table below is recommended for all
auxiliary heating requirements.
• Electric heater BTUH - (heater watts + motor watts) x 3.414 (see airflow table for motor watts.)
• Supply circuit protective devices may be fused or “HACR” type circuit breakers.
• If non-standard fuse size is specified, use next size larger standard fuse size.
• Largest motor load is included in single circuit or circuit 1 of multiple circuits.
• No electrical heating elements are permitted to be used with A Voltage (115V) air handler.
• J voltage (230V) single phase air handler is designed to be used with single or three phase
230 volt electric heaters. In the case of connecting 3 phase power to air handler terminal block
without the heater, bring only two leads to terminal block, cap, insulate and fully secure the
third lead.
• Do not use 480 volts electrical heaters on 230 volts air handler.
Electrical Wiring:
Power Wiring
Field wiring must comply with the National Electrical Code
(C.E.C. in Canada) and any applicable local ordinance.
Supply wiring must be 75°C minimum copper conductors only.
See electrical data for product Ampacity rating and Circuit
Protector requirement.
Grounding
This product must be sufficiently grounded in accordance with
National Electrical Code (C.E.C. in Canada) and any applicable
local ordinance.
A grounding lug is provided.