16.0
Rheem Classic
®
Series
Air Conditioners
FORM NO. A11-220 REV. 1
New composite base pan – dampens sound, captures louver
panels, eliminates corrosion and reduces number of fasteners
needed
Powder coat paint system – for a long lasting professional finish
Scroll compressor – uses 70% fewer moving parts for higher
efficiency and increased reliability
Modern cabinet aesthetics – increased curb appeal with visu-
ally appealing design
Curved louver panels – provide ultimate coil protection,
enhance cabinet strength, and increased cabinet rigidity
Optimized fan orifice – optimizes airflow and reduces unit
sound
Rust resistant screws – confirmed through 1500-hour salt
spray testing
PlusOne™ Expanded Valve Space – 3"-4"-5" service valve
space – provides a minimum working area of 27-square
inches for easier access
PlusOne™ Triple Service Access – 15" wide, industry lead-
ing corner service access – makes repairs easier and faster.
The two fastener removable corner allows optimal access to
internal unit components. Individual louver panels come out
once fastener is removed, for faster coil cleaning and easier
cabinet reassembly
Diagnostic service window with two-fastener opening –
provides access to the high and low pressure.
External gauge port access – allows easy connection of
“low-loss” gauge ports
Single-row condenser coil – makes unit lighter and allows
thorough coil cleaning to maintain “out of the box”
performance
35% fewer cabinet fasteners and fastener-free base – allow
for faster access to internal components and hassle-free
panel removal
Service trays – hold fasteners or caps during service calls
QR code – provides technical information on demand for
faster service calls
Fan motor harness with extra long wires allows unit top to be
removed without disconnecting fan wire.
Air
Air Conditioners
RA14 Series
“Proper sizing and installation of equipment is critical to achieve
optimal performance. Ask your Dealer for details or visit
www.energystar.gov.”
RA14 Series
Efficiencies up to 16 SEER/13 EER
Nominal Sizes 1
1
/2 to 5 Ton [5.28 to 17.6 kW]
Cooling Capacities 17.3 to 60.5 kBTU
[5.7 to 17.7 kW]
Zobrazit stránku 0
1 2 3 4 5 6 ... 43 44

Shrnutí obsahu

Strany 1 - Air Conditioners

16.0Rheem Classic®SeriesAir ConditionersFORM NO. A11-220 REV. 1• New composite base pan – dampens sound, captures louverpanels, eliminates corrosion a

Strany 2 - TABLE OF CONTENTS

Unit DimensionsMODELNO.OPERATING SHIPPINGH (Height) L (Length) W (Width) H (Height) L (Length) W (Width)INCHES mm INCHES mm INCHES mm INCHES mm INCHES

Strany 3 - Available SKUs

6⬙ (152.4)24⬙ (609.6)Service12⬙ (304.8)6⬙ (152.4)24⬙ (609.6)Service24⬙ (609.6)24⬙ recommended12⬙ minimum12⬙ (304.8)12⬙ (304.8)6⬙ (152.4)24⬙ (609.6)Ser

Strany 4 - Features & Benefits

FIGURE 2CONTROL WIRING FOR GAS OR OIL FURNACEFOR TYPICAL ELECTRIC HEATFOR TYPICAL GAS OR OIL HEATCYGWRW/BLRW/BKG/BKYLBRPUYGWRTYPICAL THERMOSTATSUBBASE

Strany 5 - Optional Accessories

AirRefrigerant Line Size InformationRA14 Series13R-410A SystemCapacity ModelLiquid Line SizeConnection Size(Inch I.D.) [mm]Liquid Line Size(Inch O.D.)

Strany 6

AirRefrigerant Line Size InformationRA14 Series14R-410A SystemCapacity ModelVapor LineConnection Size(Inch I.D.) [mm]Vapor Line Size(Inch O.D.) [mm]Va

Strany 7 - (For Reference)

15AirPerformance DataRA14 SeriesPerformance Data @ AHRI Standard Conditions – CoolingHigh Sales Volume Tested Combination (HSVTC)OutdoorUnitIndoor Coi

Strany 8 - Electrical Data

AirPerformance DataRA14 Series16Performance Data @ AHRI Standard Conditions – Cooling (con’t.)Coil Only RatingsOutdoorUnitIndoor CoilTotal CapacityBTU

Strany 9 - Thermostats

AirPerformance DataRA14 Series17Performance Data @ AHRI Standard Conditions – Cooling (con’t.)RGPT: Single Stage Upflow Constant Torque 80% Furnace R

Strany 10 - Unit Dimensions

18AirPerformance DataRA14 Series18Performance Data @ AHRI Standard Conditions – Cooling (con’t.)RGPT: Single Stage Upflow Constant Torque 80% Furnace

Strany 11 - CLEARANCES

19AirPerformance DataRA14 Series19Performance Data @ AHRI Standard Conditions – Cooling (con’t.)RGPT: Single Stage Upflow Constant Torque 80% Furnace

Strany 12 - Control Wiring

AirTable of ContentsRA14 Series2TABLE OF CONTENTSStandard Feature ...

Strany 13

AirPerformance DataRA14 Series20Performance Data @ AHRI Standard Conditions – Cooling (con’t.)RGPE: Two-Stage, Variable Speed 80% (upflow/horizontal)

Strany 14

21AirPerformance DataRA14 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)RGPE: Two-Stage, Variable Speed 80% (upflow/horizontal)

Strany 15 - RA14 Series

22AirPerformance DataRA14 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)RGPE: Two-Stage, Variable Speed 80% (upflow/horizontal)

Strany 16

23AirPerformance DataRA14 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)RGPE: Two-Stage, Variable Speed 80% (upflow/horizontal)

Strany 17

24AirPerformance DataRA14 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)R95T: 95% AFUE single-stage Constant Torque Multipoise G

Strany 18

25AirPerformance DataRA14 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)R95T: 95% AFUE single-stage Constant Torque Multipoise G

Strany 19

26AirPerformance DataRA14 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)R96V: 96% AFUE 2-stage Variable Speed Multipoise Gas Fur

Strany 20

27AirPerformance DataRA14 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)R96V: 96% AFUE 2-stage Variable Speed Multipoise Gas Fur

Strany 21

28AirPerformance DataRA14 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)R96V: 96% AFUE 2-stage Variable Speed Multipoise Gas Fur

Strany 22

29AirPerformance DataRA14 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)RGFG: 95 Plus Communicating Modulating Upflow Gas Furnac

Strany 23

AirStandard Feature/Available SKUsRA14 Series3STANDARD FEATURESFeature 18 24 30 36 42 48 60R-410a Refrigerant √ √ √ √ √ √ √Maximum SEER 16 16 16 16 16

Strany 24

30AirPerformance DataRA14 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)RGFG: 95 Plus Communicating Modulating Upflow Gas Furnac

Strany 25

31AirPerformance DataRA14 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)RGFG: 95 Plus Communicating Modulating Upflow Gas Furnac

Strany 26

32AirPerformance DataRA14 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)RGGE: 90 Plus Communicating Modulating Downflow Gas Furn

Strany 27

33AirPerformance DataRA14 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)RGGE: 90 Plus Communicating Modulating Downflow Gas Furn

Strany 28

34AirPerformance DataRA14 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)RGJF: 90 Plus Communicating Modulating Horizontal Gas Fu

Strany 29

35AirPerformance DataRA14 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)RGJF: 90 Plus Communicating Modulating Horizontal Gas Fu

Strany 30

36AirPerformance DataRA14 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)RGJF: 90 Plus Communicating Modulating Horizontal Gas Fu

Strany 31

37AirPerformance DataRA14 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)RGJF: 90 Plus Communicating Modulating Horizontal Gas Fu

Strany 32

38AirPerformance DataRA14 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)Air Handler RatingsOutdoorUnitAir HandlerTotal CapacityB

Strany 33

39AirPerformance DataRA14 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)Air Handler RatingsOutdoorUnitAir HandlerTotal CapacityB

Strany 34

The RA14 is our 14 SEER air conditioner and is part of theRheem air conditioner product line that extends from 13 to 20SEER. This highly featured and

Strany 35

AirGuide SpecificationsRA14 Series40GUIDE SPECIFICATIONS GeneralSystem DescriptionOutdoor-mounted, air-cooled, split-system air conditioner com-posite

Strany 36

AirLimited WarrantyRA14 Series41GENERAL TERMS OF LIMITED WARRANTY*Rheem will furnish a replacement for any part of this productwhich fails in normal u

Strany 37

AirNotesRA14 Series42

Strany 38

AirNotesRA14 Series43

Strany 39

The new degree of comfort.™Rheem Heating, Cooling & Water Heating • P.O. Box 17010 Fort Smith, Arkansas 72917 • www.rheem.com In keeping with

Strany 40 - Products

AirFeatures & BenefitsRA14 Series5The entire cabinet has powder post paint ( ) achieving 1000hour salt spray rating, allowing the cabinet to retai

Strany 41

RA 14 24 AJ1 N A *Brand ProductCategorySEER CapacityBTU/HRMajor Series* Voltage Type Controls Minor Series** Option CodeRheem A - Air Conditioners 13

Strany 42

R96 V A702 3 17 M S ABrand Series Motor Major Rev InputBTU/HRStages Air Flow CabinetWidthConfiguration Nox Minor RevRheem 90 - 90 AFUE92 - 92 AFUE95 -

Strany 43

AirGeneral Data/Electrical DataRA14 Series8Physical DataPHYSICAL DATAModel No. RA1418A RA1424A RA1430A RA1436A RA1442A RA1448A RA1460ANominal Tonnage

Strany 44 - The new degree of comfort

AirAccessories/Weighted Sound Power/ThermostatsRA14 Series9AccessoriesModel No. RA1418 RA1424 RA1430 RA1436 RA1442 RA1448 RA1460Compressor crankcase h