INSTALLATION & OPERATING
INSTRUCTIONS
Catalog No. 6000.553C Effective: 06-28-13 Replaces: 11-01-11 P/N 241429 Rev. 4
92-103778-02-05
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and
liquids or other combustible materials in the vicinity of this or any other appliance. To
do so may result in an explosion or fire.
Heat Pump
Pool & Spa
Heater
USC
L
I
S
T
E
D
R
NOTE: The instructions in this manual are for the use of qualified individuals specially trained and experienced
in the installation and maintenance of this type of equipment and related system components. Installation and
service personnel are required by some states to be licensed. Persons not qualified shall not attempt to install,
service, or maintain this equipment.
This manual should be maintained in legible condition and kept adjacent to the heat pump pool heater or in a
safe place for future use.
Model Series
2350, 3350,
4350, 4350PD
Zobrazit stránku 0
1 2 3 4 5 6 ... 19 20

Shrnutí obsahu

Strany 1 - Pool & Spa

INSTALLATION & OPERATINGINSTRUCTIONSCatalog No. 6000.553C Effective: 06-28-13 Replaces: 11-01-11 P/N 241429 Rev. 4 92-103778-02-05FOR YOUR

Strany 2 - Water Chemistry

System Start-Up1. Verify that the Digital Board is displaying a temper-ature and the pool pump is running and water iscirculating properly.2

Strany 3 - CONTENTS

TroubleshootingIf your unit does not operate, or simply does not heatyour pool water, Fault Codes on the front controlpanel, can provide valua

Strany 4 - Pay Attention to These Terms

• Is airflow through the unit being obstructed?Restrictions such as shrubbery, tall grass, dirtycoils, or any other obstruction to airflow

Strany 5 - Installation Considerations

Fault Code Meaning of CodeOFF The desired programmed temperature point is lower than 60°F (15°C).LP & LP3Shortage of refrigerant gas in the unit o

Strany 6 - Electrical Connections

Plumbing DiagramsFig. 5: For systems with pumps of less than 1-1/2 HP (under 50 gpm), no externalbypass is required. Connections are 1-1/2 inch unions

Strany 7

Fig. 6: For systems with pumps of 1-1/2 HP or greater (over 50 gpm), an externalbypass is required. Adjust the bypass valve to divert a minimum of 15

Strany 8 - Water Connections

Fig. 7: Pool Piping for Heat Pump Pool Heater and Gas Pool Heater16

Strany 9 - Instructions

Fig. 8: Pool Piping for Heat Pump Pool Heaters, Multiple, Primary/SecondaryBRANCH MAIN BRANCH MAIN BRANCH MAIN15 GPM 1-1/2" 1-1/2" 15 GPM 1-

Strany 10 - Freeze Protection

Wiring Diagram - 208V/230V Single-Phase18

Strany 12 - Service Call Verification

Water Chemistry(Corrosive water voids all warranties)For your health and the protection of your pool equipment, it is essential that your water be che

Strany 13 - Heater Settings

20Raypak, Inc., 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 Fax (805) 278-5468Heat Pump Service 1-800-260-2758Litho in U.S.A.

Strany 14 - Plumbing Diagrams

Water Chemistry 2Warnings 4Pay Attention to These Terms 4Introduction 5Installation Considerations 5Electrical Connections 6Water Connections 8Contro

Strany 15

CAUTION: Improper chemical content in a swim-ming pool or spa can damage the heat pump poolheater. DO NOT add pool chemicals to the skim

Strany 16

IntroductionThis manual contains important information on theuse, maintenance and troubleshooting of your newheat pump pool heater. Th

Strany 17

Table A: Typical System Electrical Power Requirements60” (1.52m)MIN12” (0.3m)MIN3 ft. (0.9m)MINFig. 1: Installation ClearancesElectrical ConnectionsRe

Strany 18

7PAD SPECIFICATION:GREATER THAN OR EQUAL TO 4” THICK SOLID CONCRETE 3000 P. S. I. OR GREATER LOAD RATINGPAD LENGTH GREATER THAN OR EQUAL TO UNIT LENGT

Strany 19

8Fig. 3: Utility ConnectionsNOTE: Units are provided with 1/4” service ports, asshown in Fig. 3 above. The upper port is for meas-uring high pressu

Strany 20 - Litho in U.S.A

ControlsYour heat pump pool heater incorporates digital safetycontrols and indicators to ensure its safe, reliableoperation.Water Pressure Swit